oalogo2  

AUTHOR(S): 

Şahi̇n Yildirim, Cem A. Gürgan

 

TITLE

Position Control and Performance Analysis of Experimental Fully-Automated Electro-Mechanical System in Inra-Oral Photography

pdf PDF

 

ABSTRACT

In spite of advanced and high technology, there are still some problems for positioning head and chin of patients during photographic recording in dentistry. Furthermore, it is very important to get reproducible photographic images for the evaluation of the intraoral treatments. In this experimental and simulation studies, a new designed system method is introduced for complex through collection of standardized intraoral photographs and computer assisted measurement of reproducible data. However, PLC based fully automated a photograpic device for fully automated intraoral photography and standart protocol for the esthetic of the crown-mucoginvigal complex is also presented. On the other hand, to test the proposed system a neural network was used to predict real time measured values.

 

KEYWORDS

Electro-mechanical system, PLC controller, dental patients, oral photographs, photograpic device, neural predictors

 

REFERENCES

 

[1] A. M. Graham and M. Etezadi-Amoli, Design, implementation and simulation of PLC based speed controller using fuzzy logic,”in Proc. IEEE Power Eng. Soc. Summer Meeting, Vol. 4, 2000, pp. 2475–2480.

[2] A. A. Ghandakly, M. E. Shields, and M. E. Brihoum, Design of an adaptive controller for a DC motor within an existing PLC framework, in Proc. Conf. Rec. 31st IEEE Industry Applications Society Annu. Meeting, Vol. 3, 1996, pp. 1567–1574.

[3] A. S. Zein El Din, High performance PLC controlled stepper motor in robot manipulator, in Proc. EEE Int. Symp. Industrial Electronics, Vol. 2, 1996, pp. 974–978.

[4] A. Hossain and A. Ahmed,“A new integrated controller for switched reluctance motor,”in Proc. Conf. Rec. 30th IEEE Industry Applications Society Annu. Meeting, Vol. 3, 1995, pp. 1917–1921.

[5] J. F. Gieras, P. D. Hartzenberg, I. J. Magura, and M. Wing, Control of an elevator drive with a single-sided linear induction motor, in Proc. 5th Eur. Conf. Power Electronics and Applications, Vol. 4, 1993, pp. 353–358. Şahi̇n Yildirim, Cem A. Gürgan

[6] V. E. Wagner, A. A. Andreshak, and J. P. Staniak, Power quality and factory automation, IEEE Trans. Ind. Applications, Vol. 26, pp. 620–626, July/Aug. 1990.

[7] M. Olsson and J. Lindhe, Periodontal characteristics in individuals with varying form of the upper central incisors. J Clin Periodontol, Vol. 18, 1991; pp. 78-82.

[8] JH. Fu, CY. Yeh, HL. Chan, N. Tatarakis, DJM. Leong and HL, Tissue biotype and its relation to the underlying bone morphology. J Periodontol, Vol. 80, 2010, pp. 569–574.

[9] RT. Kao, MC. Fagan, GJ. Conte, Thick vs. thin gingival biotypes: a key determinant in treatment planning for dental implants, J Calif Dent Assoc., Vol. 36, 2008, pp. 193–198.

[10] C. Baldi, G. Piniprato, U. Pagliaro et al., Coronally advanced flap procedure for root coverage. Is flap thickness a relevant predictor to achieve root coverage? A 19 case series. J Periodontol, Vol. 70, 1999, pp. 1077–1084.

[11] R. Pontoriero, G. Carnevale, Surgical crown lengthening: a 12-month clinical wound healing study. J Periodontol, Vol. 72, 2001, pp. 841–848.

[12] HP. Muller, N. Schaller, T. Eger, Heinecke A. Thickness of masticatory mucosa. J Clin Periodontol, Vol. 27, 2000, pp. 431–436.

[13] RT. Kao, K. Pasquinelli, Thick vs. thin gingival tissue: a key determinant in tissue response to disease and restorative treatment, J Calif Dent Assoc. Vol. 30, 2002, pp. 521–526.

[14] Berglundh T, Lindhe J. Dimensions of the peri-implant mucosa. Biological width re-visited. J Clin Periodontol, Vol. 23, 1996, pp. 971–973.

[15] Ş. Yıldırım, and İ. Eski, Noise Analysis Of Robot Manipulator Using Neural Networks, Robotics and Computer-Integrated Manufacturing, Vol.26, 2010, pp.282-290.

[16] Ş. Yıldırım, Vibration Control of Suspensions Using a Proposed Neural Network, Journal of Sound and Vibration, Vol. 27, 2004, pp. 1059-1069.

 

Cite this paper

Şahi̇n Yildirim, Cem A. Gürgan. (2017) Position Control and Performance Analysis of Experimental Fully-Automated Electro-Mechanical System in Inra-Oral Photography. International Journal of Biology and Biomedicine, 2, 42-49

 

cc.png
Copyright © 2017 Author(s) retain the copyright of this article.
This article is published under the terms of the Creative Commons Attribution License 4.0